1. Select the appropriate Answer Signaling Type on the FXS port.
Answer Signaling is required when SETU ATA211G has a PCO/Billing machine connected on its FXS port.
When a call is made through SETU ATA211G and the called party answers the call, call maturity signal
must be generated on the FXS port of SETU ATA211G so that the PCO/Billing device connected to its FXS
port can start billing. In the absence of maturity information on the FXS port, the call will not be considered
as matured, resulting in inaccurate billing.
• Select None if no answer signaling is to be generated on the FXS port.
• Select Polarity Reversal if answer signaling is to be generated in the form of Polarity Reversal on the
FXS port.
Default: Polarity Reversal.
2. Select the appropriate Disconnect Signaling Type on the FXS port.
If a PCO machine is connected to the FXS port of the SETU ATA211G, whenever the Called Party (remote
party) disconnects, the FXS port of SETU ATA211G needs to be informed of this event in the form of a
signal, so that the PCO machine can consider the call as complete and stop billing. In the absence of such
a signal, the call will be considered as completed only when the Caller goes On-hook, resulting in
inaccurate billing.
• Select None if no signaling is to be generated on FXS for call disconnection.
• Select Polarity Reversal if call disconnection is to be signaled in the form of Polarity Reversal.
• Select Open Loop Disconnect if call disconnection is to be signaled in the form of Open Loop
Disconnect signal.
If you select this option, you must configure the Open Loop Disconnect Timer.